Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 45
Filtrar
1.
Polymers (Basel) ; 15(5)2023 Feb 23.
Artigo em Inglês | MEDLINE | ID: mdl-36904369

RESUMO

This study investigates the effect of the curing mode (dual-cure vs. self-cure) of resin cements (four self-adhesive and seven conventional cements) on their flexural strength and flexural modulus of elasticity, alongside their shear bond strength to lithium disilicate ceramics (LDS). The study aims to determine the relationship between the bond strength and LDS, and the flexural strength and flexural modulus of elasticity of resin cements. Twelve conventional or adhesive and self-adhesive resin cements were tested. The manufacturer's recommended pretreating agents were used where indicated. The shear bond strengths to LDS and the flexural strength and flexural modulus of elasticity of the cement were measured immediately after setting, after one day of storage in distilled water at 37 °C, and after 20,000 thermocycles (TC 20k). The relationship between the bond strength to LDS, flexural strength, and flexural modulus of elasticity of resin cements was investigated using a multiple linear regression analysis. For all resin cements, the shear bond strength, flexural strength, and flexural modulus of elasticity were lowest immediately after setting. A clear and significant difference between dual-curing and self-curing modes was observed in all resin cements immediately after setting, except for ResiCem EX. Regardless of the difference of the core-mode condition of all resin cements, flexural strengths were correlated with the LDS surface upon shear bond strengths (R2 = 0.24, n = 69, p < 0.001) and the flexural modulus of elasticity was correlated with them (R2 = 0.14, n = 69, p < 0.001). Multiple linear regression analyses revealed that the shear bond strength was 17.877 + 0.166, the flexural strength was 0.643, and the flexural modulus was (R2 = 0.51, n = 69, p < 0.001). The flexural strength or flexural modulus of elasticity may be used to predict the bond strength of resin cements to LDS.

2.
Materials (Basel) ; 15(21)2022 Oct 28.
Artigo em Inglês | MEDLINE | ID: mdl-36363156

RESUMO

This study investigated the effects of a multifunctional acrylate copolymer-Trimethylolpropane Triacrylate (TMPTA) and Di-pentaerythritol Polyacrylate (A-DPH)-on the mechanical properties of chemically polymerized acrylic resin and its bond strength to a CAD/CAM polymethyl methacrylate (PMMA) disk. The methyl methacrylate (MMA) samples were doped with one of the following comonomers: TMPTA, A-DPH, or Trimethylolpropane Trimethacrylate (TMPTMA). The doping ratio ranged from 10 wt% to 50 wt% in 10 wt% increments. The flexural strength (FS) and modulus (FM) of PMMA with and without comonomer doping, as well as the shear bond strength (SBS) between the comonomer-doped PMMA and CAD/CAM PMMA disk, were evaluated. The highest FS (93.2 ± 4.2 MPa) was obtained when doped with 20 wt% of TMPTA. For TMPTMA, the FS decreased with the increase in the doping ratio. For SBS, TMPTA showed almost constant values (ranging from 7.0 to 8.2 MPa) regardless of the doping amount, and A-DPH peaked at 10 wt% doping (8.7 ± 2.2 MPa). TMPTMA showed two peaks at 10 wt% (7.2 ± 2.6 MPa) and 40 wt% (6.5 ± 2.3 MPa). Regarding the failure mode, TMPTMA showed mostly adhesive failure between the CAD/CAM PMMA disk and acrylic resin while TMPTA and A-DPH showed an increased rate of cohesive or mixed failures. Acrylate's addition as a comonomer to PMMA provided improved mechanical properties and bond strength to the CAD/CAM PMMA disk.

3.
Dent Mater J ; 41(5): 705-709, 2022 Oct 02.
Artigo em Inglês | MEDLINE | ID: mdl-35793941

RESUMO

This study uses fracture tests and fractographical analysis to compare computer-aided design and computer-aided manufacturing (CAD/CAM) lithium disilicate molar crowns with the previous occlusal thickness recommendation of 1.5-mm, the new recommendation of 1.0-mm, and a less invasive thickness of 0.8-mm. After fatigue application, fracture tests and fractographic analysis were conducted. The fracture resistance of CAD/CAM lithium disilicate molar crowns was different depending on the occlusal thickness of the restoration, and decreased with lower the thickness. However, the fracture resistance of crowns of all three thicknesses exceeded the reported maximum bite force in the first molar region after the fatigue process, and can be considered acceptable for use in the clinic.


Assuntos
Planejamento de Prótese Dentária , Falha de Restauração Dentária , Cerâmica , Desenho Assistido por Computador , Coroas , Porcelana Dentária , Análise do Estresse Dentário , Humanos , Teste de Materiais
4.
Dent Mater J ; 41(3): 429-439, 2022 May 31.
Artigo em Inglês | MEDLINE | ID: mdl-35135941

RESUMO

We sought to compare the bond strength of resin cement on moist dentin to that on dry dentin, and determine the relationship between the bond strength and flexural strength of resin cement. The water content of the moist and dry dentins was estimated using infrared spectroscopy. Four adhesive and three self-adhesive resin cements were used. At three times of immediately, after one-day storage, and after 20,000 thermocycles (TC 20k), the shear bond strengths were measured. For all resin cements, both the shear bond strength and the flexural strength were the lowest immediately after setting; however, after one day of water storage or TC 20k, these resin cements had the highest values. Regardless of the condition of the dentin surface upon shear bond strength, the flexural strength of each resin cement was correlated with the shear bond strength of the dentin surface.


Assuntos
Colagem Dentária , Cimentos de Resina , Dentina , Adesivos Dentinários/química , Resistência à Flexão , Teste de Materiais , Cimentos de Resina/química , Resistência ao Cisalhamento , Estresse Mecânico , Propriedades de Superfície , Água/química
5.
Polymers (Basel) ; 13(16)2021 Aug 06.
Artigo em Inglês | MEDLINE | ID: mdl-34451153

RESUMO

To evaluate the flexural and bonding properties, marginal adaptation, and polymerization shrinkage in flowable composite restorations and their relationships, four new generation flowable composites, one conventional, and one bulk-fill flowable composite were used in this study. Flexural properties of the composites and shear bond strength to enamel and dentin for flowable restorations were measured immediately and 24 h after polymerization. Marginal adaptation, polymerization shrinkage, and stress were also investigated immediately after polymerization. The flexural properties, and bond strength of the flowable composites to enamel and dentin were much lower immediately after polymerization than at 24 h, regardless of the type of the composite. Polymerization shrinkage and stress varied depending on the material, and bulk-fill flowable composite showed much lower values than the others. The marginal adaptation and polymerization shrinkage of the composites appeared to have a much stronger correlation with a shear bond strength to dentin than to enamel. The weak mechanical properties and bond strengths of flowable composites in the early stage after polymerization must be taken into account when using them in the clinic. In addition, clinicians should be aware that polymerization shrinkage of flowable composites can still lead to the formation of gaps and failure of adaptation to the cavity regardless of the type of composite.

6.
Polymers (Basel) ; 12(12)2020 Dec 09.
Artigo em Inglês | MEDLINE | ID: mdl-33317215

RESUMO

The aims of this study were to investigate the effects of root dentin shear bond strength and pull-out force of resin core build-up materials on flexural strength immediately after setting, after one-day water storage, and after 20,000 thermocycles. Eight core build-up and three luting materials were investigated, using 10 specimens (n = 10) per subgroup. At three time periods-immediately after setting, after one-day water storage, and after 20,000 thermocycles, shear bond strengths to root dentin and pull-out forces were measured. Flexural strengths were measured using a 3-point bending test. For all core build-up and luting materials, the mean data of flexural strength, shear bond strength and pull-out force were the lowest immediately after setting. After one-day storage, almost all the materials yielded their highest results. A weak, but statistically significant, correlation was found between flexural strength and shear bond strength (r = 0.508, p = 0.0026, n = 33). As the pull-out force increased, the flexural strength of core build-up materials also increased (r = 0.398, p = 0.0218, n = 33). Multiple linear regression analyses were conducted using these three independent factors of flexural strength, pull-out force and root dentin shear bond strength, which showed this relationship: Flexural strength = 3.264 × Shear bond strength + 1.533 × Pull out force + 10.870, p = 0.002). For all the 11 core build-up and luting materials investigated immediately after setting, after one-day storage and after 20,000 thermocycles, their shear bond strengths to root dentin and pull-out forces were correlated to the flexural strength in core build-up materials. It was concluded that the flexural strength results of the core build-up material be used in research and quality control for the predictor of the shear bond strength to the root dentin and the retentive force of the post.

7.
J Appl Biomater Funct Mater ; 18: 2280800020942717, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-33032503

RESUMO

This study investigated the mechanical properties, bond ability, and crystallographic forms of different sites in a highly translucent, multi-layered zirconia disk. Flexural properties, bond ability to resin cement, and phase composition were investigated at three sites of a highly translucent, multi-layered zirconia disk: incisal, middle, and cervical. Flexural strength (FS) and flexural modulus (FM) were measured with static three-point flexural test. Shear bond strength (SB) to resin cement was measured after 24 h storage (37°C). Phase composition under mechanical stress was analyzed using X-ray diffraction. Without air abrasion, FS at the incisal site yielded the lowest value and was significantly lower than the middle and cervical sites. Air abrasion lowered the FS of each site. FM at the incisal site without air abrasion showed the significantly lowest value, and air abrasion increased its FM value. At the middle and cervical sites, their FM values were higher than the incisal site but were not significantly affected by air abrasion. SB value did not show significant differences among the sites. After sintering, cubic zirconia was detected at each site. Rhombohedral phase transformation occurred after mirror polishing. In highly translucent, multi-layered zirconia which was mainly composed of cubic zirconia, rhombohedral phase transformation occurred under mechanical stress and resulted in weakened mechanical properties.


Assuntos
Teste de Materiais , Cimentos de Resina , Resistência ao Cisalhamento , Zircônio/química , Cristalografia por Raios X , Materiais Dentários , Desenho de Equipamento , Resistência à Flexão , Estresse Mecânico , Propriedades de Superfície , Resistência à Tração , Difração de Raios X
8.
J Mater Chem B ; 8(24): 5320-5329, 2020 06 24.
Artigo em Inglês | MEDLINE | ID: mdl-32458954

RESUMO

Several studies have shown the clinical success of hydraulic calcium-silicate cements (hCSCs) for direct and indirect pulp capping and root repair. However, hCSCs have various drawbacks, including long setting time, poor mechanical properties, low bond strength to dentin, and relatively poor handling characteristics. To overcome these limitations, a light-curable, resin-based hCSC (Theracal LC, Bisco) was commercially introduced; however, it did not exhibit much improvement in bond strength. We developed a light-curable self-adhesive pulp-capping material that contains the novel acrylamide monomer N,N'-{[(2-acrylamido-2-[(3-acrylamidopropoxy)methyl]propane-1,3-diyl)bis(oxy)]bis(propane-1,3-diyl)}diacrylamide (FAM-401) and the functional monomer 4-methacryloxyethyl trimellitate anhydride (4-MET). Two experimental resin-based hCSCs containing different calcium sources (portlandite: Exp_Pl; tricalcium silicate cement: Exp_TCS) were prepared, and the commercial hCSCs Theracal LC and resin-free hCSC Biodentine served as controls. The performance of each cement was evaluated based on parameters relevant for vital pulp therapy, such as curing degree on a wet surface, mechanical strength, as determined using a three-point bending test, shear bond strength to dentin, cytotoxicity, as determined using an MTT assay, and the amount of calcium released, as determined using inductively coupled plasma atomic emission spectrometry. Both experimental cements cured on wet surfaces and showed relatively low cytotoxicity. Furthermore, their flexural and shear bond strength to dentin were significantly higher than those of the commercial references. High calcium release was observed for both Exp_Pl and Biodentine. Thus, Exp_Pl as a new self-adhesive pulp-capping agent performed better than the commercial resin-based pulp-capping agent in terms of mechanical strength, bond strength, and calcium release.


Assuntos
Acrilamida/química , Agentes de Capeamento da Polpa Dentária e Pulpectomia/síntese química , Cimentos de Resina/síntese química , Acrilamida/farmacologia , Animais , Sobrevivência Celular/efeitos dos fármacos , Células Cultivadas , Cricetinae , Cricetulus , Interações Hidrofóbicas e Hidrofílicas , Teste de Materiais , Estrutura Molecular , Tamanho da Partícula , Polimerização , Agentes de Capeamento da Polpa Dentária e Pulpectomia/química , Agentes de Capeamento da Polpa Dentária e Pulpectomia/farmacologia , Cimentos de Resina/química , Cimentos de Resina/farmacologia , Propriedades de Superfície
9.
Dent Mater ; 35(7): 970-978, 2019 07.
Artigo em Inglês | MEDLINE | ID: mdl-31006551

RESUMO

OBJECTIVE: To assess whether a thermal annealing with a monoclinic zirconia (mZrO2) nanoparticle coating can improve the reliability of sandblasted yttria-stabilized tetragonal zirconia polycrystals (Y-TZP) and maintain its mechanical strength. METHODS: Commercially available Y-TZP (Lava Frame, 3M Dental Products) disks were sintered and surface-treated as follows: AS (as sintered, with no treatment); SB (sandblasting); SB-TA (sandblasting followed by thermal annealing at 1000 °C); and SB-mZr-TA (sandblasting followed by thermal annealing at 1000 °C with the mZrO2 nanoparticle coating). The mZrO2 nanoparticles of 21 nm in size were prepared by a hydrothermal method, and coated onto Y-TZP sintered disks as a 5 g/L ethanol dispersion. Biaxial flexural strength (S) was measured using the piston-on-three-ball test, and reliability was evaluated by the Weibull modulus (m). RESULTS: Biaxial flexural tests showed a significant increase in the strength of Group SB (SSB = 1445 ± 191 MPa) compared with Group AS (SAS = 1071 ± 112 MPa). The thermal annealing improved the reliabilities of the sandblasted Y-TZP (mSB-TA = 20.14 and mSB-mZr-TA = 21.33), as compared with Group SB (mSB = 7.77). However, the conventional thermal annealing without the mZrO2 coating caused a significant decrease in the strength of sandblasted Y-TZP (SSB-TA = 1273 ± 65 MPa). Importantly, the mZrO2 coating prevented the decrease in the strength caused by conventional thermal annealing (SSB-mZr-TA = 1379 ± 65 MPa). SIGNIFICANCE: The thermal annealing with the mZrO2 nanoparticle coating can improve the reliability of sandblasted Y-TZP and maintain its mechanical strength, which would otherwise be decreased by the conventional annealing process.


Assuntos
Nanopartículas , Ítrio , Materiais Dentários , Teste de Materiais , Reprodutibilidade dos Testes , Propriedades de Superfície , Zircônio
10.
Dent Mater ; 35(1): 169-175, 2019 01.
Artigo em Inglês | MEDLINE | ID: mdl-30502226

RESUMO

OBJECTIVE: To assess the influence of sandblasting conditions applied to conventional-type yttria-stabilized tetragonal zirconia polycrystal (Y-TZP) on surface roughness, phase transformation, and biaxial flexural strength. METHODS: Commercially available Y-TZP (Lava Frame, 3M Dental Products) disks were used after sintering (specimen dimensions: 14mm in diameter and 1.2mm in thickness). The surfaces of specimens were ground, and then sandblast treatments were conducted at different pressures (0.20, 0.25, 0.30, 0.35 and 0.40MPa) and distances (1, 5, 10 and 20mm) with 50µm alumina particles. Surface roughness measurements were performed and scanning electron microscopy (SEM) images were taken for surface characterizations. Phase transformation of Y-TZP was identified by X-ray diffraction (XRD). Biaxial flexural strength was measured using the piston-on-three-ball test. RESULTS: The surface roughness increased significantly by increasing the sandblasting pressure, and microcracks were observed at high sandblasting pressure at 0.40MPa. The shortest sandblasting distance (1mm) was not effective to increase the surface roughness compared with other sandblasting distances. A tetragonal to monoclinic phase transformation was observed after grinding. The degree of the phase transformation tended to increase with sandblasting pressure, and significant effect was independent of the sandblasting distance. The biaxial flexural test showed improved mechanical strengths for the samples after sandblasting at 0.20-0.35MPa, with the maximum strength at 0.25MPa. Sandblasting at 0.40MPa decreased the strength as compared with 0.25MPa. SIGNIFICANCE: The surface roughness increased with increasing the sandblasting pressure, whereas there was an optimal sandblasting pressure range to increase biaxial flexural strength of Y-TZP.


Assuntos
Materiais Dentários , Ítrio , Teste de Materiais , Propriedades de Superfície , Zircônio
11.
PLoS One ; 12(8): e0183381, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-28817736

RESUMO

This study investigated the effects on gap formation in Class I restorations (observed by vertical and horizontal forms of inspection) and on the mechanical properties of nine resin composite filling materials when the restorations were subject to finishing immediately after setting or after one-day water storage. Class I restorations with resin composite fillings were polished either immediately (3 min) after setting or after one-day water storage. Interfacial gap formation (observed by vertical inspection) was assessed using 14 gap measurement points along the interface between the restoration and cavity walls and floor (n = 10 per resin composite; total points measured per time point = 140). For marginal gaps formed at cavosurface margins in Class I cavities and in Teflon molds, marginal gap formation (observed by horizontal inspection) was assessed by measuring the maximum gap-width and opposing width (if any). Effects on mechanical properties were assessed by measuring shear bond strengths to enamel and dentin, flexural strength and modulus. After one-day storage, marginal gap-widths in Class I restorations were significantly decreased for all composites, alongside a significant increase in shear bond strengths to enamel and dentin, flexural strength and modulus. Resin composite-filled Class I restorations which were polished after one-day delay presented lower gap formation compared with finishing immediately after setting.


Assuntos
Resinas Compostas , Polimento Dentário , Água , Humanos
12.
Dent Mater J ; 36(5): 600-605, 2017 Sep 26.
Artigo em Inglês | MEDLINE | ID: mdl-28566673

RESUMO

Resin bonding to zirconia ceramics is difficult to achieve using the standard methods for conventional silica-based dental ceramics, which employ silane coupling monomers as primers. The hypothesis in this study was that a silane coupling oligomer -a condensed product of silane coupling monomers- would be a more suitable primer for zirconia. To prove this hypothesis, the shear bond strengths between a composite resin and zirconia were compared after applying either a silane coupling monomer or oligomer. The shear bond strength increased after applying a non-activated ethanol solution of the silane coupling oligomer compared with that achieved when applying the monomer. Thermal treatment of the zirconia at 110°C after application of the silane coupling agents was essential to improve the shear bond strength between the composite resin cement and zirconia.


Assuntos
Cerâmica , Colagem Dentária , Cimentos de Resina , Zircônio , Porcelana Dentária , Teste de Materiais , Resistência ao Cisalhamento , Silanos , Propriedades de Superfície
13.
Sci Rep ; 7: 45563, 2017 03 30.
Artigo em Inglês | MEDLINE | ID: mdl-28358121

RESUMO

Currently, the functional monomer 10-methacryloyloxy-decyl-dihydrogen-phosphate (10-MDP) was documented to chemically bond to zirconia ceramics. However, little research has been conducted to unravel the underlying mechanisms. This study aimed to assess the chemical interaction and to demonstrate the mechanisms of coordination between 10-MDP and zirconium oxide using 1H and 31P magic angle spinning (MAS) nuclear magnetic resonance (NMR) and two dimensional (2D) 1H → 31P heteronuclear correlation (HETCOR) NMR. In addition, shear bond-strength (SBS) tests were conducted to determine the effect of 10-MDP concentration on the bonding effectiveness to zirconia. These SBS tests revealed a 10-MDP concentration-dependent SBS with a minimum of 1-ppb 10-MDP needed. 31P-NMR revealed that one P-OH non-deprotonated of the PO3H2 group from 10-MDP chemically bonded strongly to zirconia. 1H-31P HETCOR NMR indicated that the 10-MDP monomer can be adsorbed onto the zirconia particles by hydrogen bonding between the P=O and Zr-OH groups or via ionic interactions between partially positive Zr and deprotonated 10-MDP (P-O-). The combination of 1H NMR and 2D 1H-31P HETCOR NMR enabled to describe the different chemical states of the 10-MDP bonds with zirconia; they not only revealed ionic but also hydrogen bonding between 10-MDP and zirconia.

14.
Dent Mater ; 33(3): e124-e135, 2017 03.
Artigo em Inglês | MEDLINE | ID: mdl-28057347

RESUMO

OBJECTIVE: CAD-CAM blocks to fabricate semi-direct and indirect restorations are available in different sorts of ceramics as well as composite. In order to bond restorations prepared out of composite blocks into tooth cavities, it is recommended to gently sandblast the surface prior to the application of a primer/adhesive. Today, the effect of sandblasting composite block surfaces has not thoroughly been investigated. In this study, the ultra-structure of composite CAD-CAM blocks was investigated with special attention to the effect of sandblasting on the surface topography and of silanization on the bonding performance. METHODS: Five different composite CAD-CAM blocks were involved. We correlatively investigated their structural and chemical composition using X-ray diffraction (XRD), energy dispersion spectroscopy (EDS), scanning electron microscopy (SEM) and (scanning) transmission electron microscopy ((S)TEM). The effect of sandblasting was also imaged in cross-section and at the interface with composite cement. Finally, we measured the shear bond strength to the sandblasted block surface with and without silanization. RESULTS: All composite blocks revealed a different ultra-structure. Sandblasting increased surface roughness and resulted in an irregular surface with some filler exposure. Sandblasting also damaged the surface. When the sandblasted composite blocks were silanized, superior bonding receptiveness in terms of higher bond strength was achieved except for Shofu Block HC. SIGNIFICANCE: Sandblasting followed by silanization improved the bond strength to composite CAD-CAM blocks. However, sandblasting may also damage the composite CAD-CAM block surface. For the composite CAD-CAM block Shofu Block HC, the damage was so severe that silanization did not improve bond strength.


Assuntos
Resinas Compostas , Desenho Assistido por Computador , Cimentos de Resina , Colagem Dentária , Teste de Materiais , Silanos , Propriedades de Superfície
15.
Dent Mater ; 33(3): e95-e100, 2017 03.
Artigo em Inglês | MEDLINE | ID: mdl-27890356

RESUMO

OBJECTIVES: Dental ceramic surfaces are modified with silane coupling agents, such as γ-methacryloxypropyl trimethoxy silane (γ-MPTS), to improve bond strength. For bonding between lithium disilicate glass ceramic and resin cement, the objective was to investigate if 8-methacryloxyoctyl trimethoxy silane (8-MOTS) could yield a similar performance as the widely used γ-MPTS. METHODS: One hundred and ten lithium disilicate glass ceramic specimens were randomly divided into 11 groups (n=10) according to pretreatment regime. All specimens were pretreated with a different solution composed of one or a combination of these agents: 10 or 20wt% silane coupling agent of γ-MPTS or 8-MOTS, followed by a hydrolysis solution of acetic acid or 10-methacryloyloxydecyl dihydrogen phosphate (10-MDP). Each pretreated surface was luted to a stainless steel rod of 3.6mm diameter and 2.0mm height with resin cement. Shear bond strength between ceramic and cement was measured after 24-h storage in 37°C distilled water. RESULTS: 8-MOTS produced the same bonding performance as γ-MPTS. Both silane coupling agents significantly increased the bond strength of resin cement, depending on their concentration. When activated by 10-MDP hydrolysis solution, 20wt% concentration produced the highest values (γ-MPTS: 24.9±5.1MPa; 8-MOTS: 24.6±7.4MPa). Hydrolysis with acetic acid produced lower bond strengths than with 10-MDP. SIGNIFICANCE: Silane coupling pretreatment with 8-MOTS increased the initial bond strength between lithium disilicate glass ceramic and resin cement, rendering the same bonding effect as the conventional γ-MPTS.


Assuntos
Cerâmica , Colagem Dentária , Porcelana Dentária , Análise do Estresse Dentário , Teste de Materiais , Cimentos de Resina , Resistência ao Cisalhamento , Silanos , Propriedades de Superfície
16.
J Appl Biomater Funct Mater ; 15(1): e93-e100, 2017 Jan 26.
Artigo em Inglês | MEDLINE | ID: mdl-27647389

RESUMO

BACKGROUND: This study evaluated the surface morphology, chemical composition and adhesiveness of lithium disilicate glass ceramic after acid etching with hydrofluoric acid or phosphoric acid. METHODS: Lithium disilicate glass ceramic specimens polished by 600-grit silicon carbide paper were subjected to one or a combination of these surface treatments: airborne particle abrasion with 50-µm alumina (AA), etching with 5% hydrofluoric acid (HF) or 36% phosphoric acid (Phos), and application of silane coupling agent (Si). Stainless steel rods of 3.6-mm diameter and 2.0-mm height were cemented onto treated ceramic surfaces with a self-adhesive resin cement (Clearfil SA Cement). Shear bond strengths between ceramic and cement were measured after 24-hour storage in 37°C distilled water. RESULTS: SEM images of AA revealed the formation of conventional microretentive grooves, but acid etching with HF or Phos produced a porous surface. Bond strengths of AA+HF+Si (28.1 ± 6.0 MPa), AA+Phos+Si (17.5 ± 4.1 MPa) and HF+Si (21.0 ± 3.0 MPa) were significantly greater than those of non-pretreated controls with Si (9.7 ± 3.7 MPa) and without Si (4.1 ± 2.4 MPa) (p<0.05). In addition, HF etching alone (26.2 ± 7.5 MPa) had significantly higher bond strength than AA alone (11.5 ± 4.0 MPa) (p<0.05). AA+HF, AA+Phos and HF showed cohesive failures. CONCLUSIONS: Etching with HF or Phos yielded higher bond strength between lithium disilicate glass ceramic and self-adhesive resin cement without microcrack formation.


Assuntos
Porcelana Dentária/química , Vidro/química , Ácido Clorídrico/química , Ácidos Fosfóricos/química , Propriedades de Superfície
17.
Dent Mater ; 32(10): 1218-1225, 2016 10.
Artigo em Inglês | MEDLINE | ID: mdl-27461880

RESUMO

OBJECTIVE: For bonding indirect restorations, some 'universal' adhesives incorporate a silane coupling agent to chemically bond to glass-rich ceramics so that a separate ceramic primer is claimed to be no longer needed. With this work, we investigated the effectiveness/stability of the silane coupling function of the silanecontaining experimentally prepared adhesives and Scotchbond Universal (3MESPE). METHODS AND MATERIALS: Experimental adhesives consisted of Scotchbond Universal and the silane-free Clearfil S3 ND Quick (Kuraray Noritake) mixed with Clearfil Porcelain Bond Activator (Kuraray Noritake) and the two adhesives to which γ-methacryloxypropyltrimethoxysilane (γ-MPTS) was added. Shear bond strength was measured onto silica-glass plates; the adhesive formulations were analyzed using fourier transform infrared spectroscopy (FTIR) and 13C nuclear magnetic resonance (NMR). In addition, shear bond strength onto CAD-CAM composite blocks was measured without and after thermo-cycling ageing. RESULTS: A significantly higher bond strength was recorded when Clearfil Porcelain Bond Activator was freshly mixed with the adhesive. Likewise, the experimental adhesives, to which γ-MPTS was added, revealed a significantly higher bond strength, but only when the adhesive was applied immediately after mixing; delayed application resulted in a significantly lower bond strength. FTIR and (13)C NMR revealed hydrolysis and dehydration condensation to progress with the time after γ-MPTS was mixed with the two adhesives. After thermo-cycling, the bond strength onto CAD-CAM composite blocks remained stable only for the two adhesives with which Clearfil Porcelain Bond Activator was mixed. SIGNIFICANCE: Only the silane coupling effect of freshly prepared silanecontaining adhesives was effective. Clinically, the use of a separate silane primer or silane freshly mixed with the adhesive remains recommended to bond glass-rich ceramics.


Assuntos
Colagem Dentária , Metacrilatos , Cimentos de Resina , Silanos , Adesivos , Porcelana Dentária , Teste de Materiais
18.
PLoS One ; 11(1): e0147077, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-26764913

RESUMO

BACKGROUND: Sandblasting particles which remain on the surfaces of dental restorations are removed prior to cementation. It is probable that adhesive strength between luting material and sandblasting particle remnants might exceed that with restorative material. If that being the case, blasting particles adhere to sandblasted material surface could be instrumental to increasing adhesive strength like underlying bonding mechanism between luting material and silanized particles of tribochemical silica coating-treated surface. We hypothesize that ultrasonic cleaning of bonding surfaces, which were pretreated with sandblasting, may affect adhesive strength of a resin luting material to dental restorative materials. METHODS: We therefore observed adhesive strength of resin luting material to aluminum oxide was greater than those to zirconia ceramic and cobalt-chromium alloy beforehand. To measure the shear bond strengths of resin luting material to zirconia ceramic and cobalt-chromium alloy, forty specimens of each restorative material were prepared. Bonding surfaces were polished with silicon abrasive paper and then treated with sandblasting. For each restorative material, 40 sandblasted specimens were equally divided into two groups: ultrasonic cleaning (USC) group and non-ultrasonic cleaning (NUSC) group. After resin luting material was polymerized on bonding surface, shear test was performed to evaluate effect of ultrasonic cleaning of bonding surfaces pretreated with sandblasting on bond strength. RESULTS: For both zirconia ceramic and cobalt-chromium alloy, NUSC group showed significantly higher shear bond strength than USC group. CONCLUSIONS: Ultrasonic cleaning of dental restorations after sandblasting should be avoided to retain improved bonding between these materials.


Assuntos
Materiais Dentários/química , Teste de Materiais , Humanos , Fenômenos Mecânicos
19.
Biomed Mater ; 10(6): 065009, 2015 Nov 20.
Artigo em Inglês | MEDLINE | ID: mdl-26586655

RESUMO

A multifunctional biomaterial with the capacity bond to hard tissues, such as bones and teeth, is a real need for medical and dental applications in tissue engineering and regenerative medicine. Recently, we created phosphorylated-pullulan (PPL), capable of binding to hydroxyapatite in bones and teeth. In the present study, we employed PPL as a novel biocompatible material for bone engineering. First, an in vitro evaluation of the mechanical properties of PPL demonstrated both PPL and PPL/ß-TCP composites have higher shear bond strength than materials in current clinical use, including polymethylmethacrylate (PMMA) cement and α-tricalcium phosphate (TCP) cement, Biopex-R. Further, the compressive strength of PPL/ß-TCP composite was significantly higher than Biopex-R. Next, in vivo osteoconductivity of PPL/ß-TCP composite was investigated in a murine intramedular injection model. Bone formation was observed 5 weeks after injection of PPL/ß-TCP composite, which was even more evident at 8 weeks; whereas, no bone formation was detected after injection of PPL alone. We then applied PPL/ß-TCP composite to a rabbit ulnar bone defect model and observed bone formation comparable to that induced by Biopex-R. Implantation of PPL/ß-TCP composite induced new bone formation at 4 weeks, which was remarkably evident at 8 weeks. In contrast, Biopex-R remained isolated from the surrounding bone at 8 weeks. In a pig vertebral bone defect model, defects treated with PPL/ß-TCP composite were almost completely replaced by new bone; whereas, PPL alone failed to induce bone formation. Collectively, our results suggest PPL/ß-TCP composite may be useful for bone engineering.


Assuntos
Substitutos Ósseos/administração & dosagem , Substitutos Ósseos/síntese química , Fosfatos de Cálcio/química , Glucanos/química , Nanoconjugados/química , Fraturas da Ulna/terapia , Adesividade , Animais , Regeneração Óssea , Força Compressiva , Feminino , Injeções Intralesionais , Teste de Materiais , Camundongos , Camundongos Endogâmicos C57BL , Nanoconjugados/ultraestrutura , Fosforilação , Coelhos , Resistência ao Cisalhamento , Estresse Mecânico , Resistência à Tração , Resultado do Tratamento , Fraturas da Ulna/patologia
20.
Acta Odontol Scand ; 73(8): 581-7, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-25892406

RESUMO

OBJECTIVE: High flexural properties are needed for fixed partial denture or implant prosthesis to resist susceptibility to failures caused by occlusal overload. The aim of this investigation was to clarify the effects of four different kinds of fibers on the flexural properties of fiber-reinforced composites. MATERIALS AND METHODS: Polyethylene fiber, glass fiber and two types of carbon fibers were used for reinforcement. Seven groups of specimens, 2 × 2 × 25 mm, were prepared (n = 10 per group). Four groups of resin composite specimens were reinforced with polyethylene, glass or one type of carbon fiber. The remaining three groups served as controls, with each group comprising one brand of resin composite without any fiber. After 24-h water storage in 37°C distilled water, the flexural properties of each specimen were examined with static three-point flexural test at a crosshead speed of 0.5 mm/min. RESULTS: Compared to the control without any fiber, glass and carbon fibers significantly increased the flexural strength (p < 0.05). On the contrary, the polyethylene fiber decreased the flexural strength (p < 0.05). Among the fibers, carbon fiber exhibited higher flexural strength than glass fiber (p < 0.05). Similar trends were observed for flexural modulus and fracture energy. However, there was no significant difference in fracture energy between carbon and glass fibers (p > 0.05). CONCLUSION: Fibers could, therefore, improve the flexural properties of resin composite and carbon fibers in longitudinal form yielded the better effects for reinforcement.


Assuntos
Carbono/química , Materiais Dentários/química , Planejamento de Dentadura , Vidro/química , Polietileno/química , Fibra de Carbono , Resinas Compostas/química , Prótese Dentária Fixada por Implante , Análise do Estresse Dentário/instrumentação , Prótese Parcial Fixa , Módulo de Elasticidade , Humanos , Cura Luminosa de Adesivos Dentários/métodos , Teste de Materiais , Maleabilidade , Estresse Mecânico , Propriedades de Superfície , Temperatura , Fatores de Tempo , Água/química
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...